As a guest user you are not logged in or recognized by your IP address. You have
access to the Front Matter, Abstracts, Author Index, Subject Index and the full
text of Open Access publications.
A novel Eddy Current (EC) probe configurations were developed to detect millimeter defects with any orientation on inner or outer pipe surfaces. The probes were designed and experimentally validated in different materials where the defects tested were identified with a high sensitivity and good signal-to-noise ratio.